| Type | Feature | Application Scenarios | Selection Priority |
| Ordinary Indoor Fire Hydrant | The structure is simple, equipped with valves and interfaces. It needs to be installed in combination with a fire box. | Office buildings, shopping malls, residential buildings, etc. (ordinary buildings) | ★★★★★High versatility and controllable costs |
| Pressure-Reducing and Stabilizing Indoor Fire Hydrant | Built-in pressure reduction device, ensuring stable water pressure | High-rise buildings (with more than 10 floors) and areas with high water pressure | ★★★★☆ Prevent excessive water pressure from damaging the equipment or interfering with the firefighting process. |
| Rotary Indoor Fire Hydrant | The interface can rotate 360 degrees and is highly flexible to operate. | Narrow space, computer room, underground garage | ★★★☆☆Adapt to complex installation environments |
| Type | Features | Applicable Scenarios | Selection Priority |
| Above-Ground Outdoor Fire Hydrant | Exposed installation, exposed interfaces, easy to operate | Urban roads, parks, open areas | ★★★★★ Easy maintenance, high recognition rate |
| Underground Outdoor Fire Hydrant | Underground installation, with only the operation port exposed, without affecting traffic. | The city center, pedestrian street, dense commercial area | ★★★★☆ High aesthetic quality, avoiding damage from collisions |
| Anti-Collision Outdoor Fire Hydrant | Built-in buffer device, which can reset after being impacted | Parking lot, main road, construction area | ★★★☆☆Essential for high-risk areas, reducing maintenance costs |
Mistake 1: Mixing indoor and outdoor fire hydrants—outdoor fire hydrants are not corrosion-resistant and prone to rust when used indoors; indoor fire hydrants have insufficient pressure to meet the needs of large-area outdoor fire extinguishing.
Mistake 2: Concealed installation position—indoor fire hydrants blocked by debris, outdoor fire hydrants covered by greenery, delaying fire extinguishing.
Mistake 3: Ignoring anti-freezing measures—outdoor fire hydrants in northern regions not insulated, prone to freezing and cracking in winter, resulting in unusability.
As a fire hydrant manufacturer with 20 years of experience, our products combine quality and adaptability:
The entire series has passed 3C certification and ISO9001 quality system certification, with complete indoor and outdoor models, supporting customized production (such as special pressure, interface, and material requirements).
Core components are made of brass and ductile iron, corrosion-resistant and anti-aging; outdoor models are added with anti-freezing and anti-collision designs, adapting to different climates and environments.
Provide one-stop service: from selection consultation, technical scheme design to installation guidance and after-sales maintenance, the professional team follows up the whole process to ensure the equipment meets fire safety standards.